1. Home
  2. mesh piece

Sternal closure with sandwiched three-piece bioresorbable mesh

$ 11.50

4.9 (770) In stock

Background Median sternotomy is the most performed procedure in cardiac surgery; however, sternal displacement and bleeding remains a problem. This study aimed to investigate whether sternal reconstruction using a sandwiched three-piece bioresorbable mesh plate can prevent postoperative sternal displacement and bleeding more than a bioresorbable pin. Methods Patients (n = 218) who underwent median sternotomy were classified according to whether a sandwiched three-piece bioresorbable mesh plate and wire cerclage (group M, n = 109) or a bioresorbable pin and wire cerclage (group P, n = 109) were used during sternal reconstruction. The causes of postoperative sternal displacement and bleeding with computed tomography data were analyzed and compared between the groups. Results The preoperative patient characteristics did not significantly differ between the groups. However, the evaluation of sternal and substernal hematoma on postoperative day 5 using computed tomography showed sternal displacement in 4 (4%) and 22 (20%) patients, and substernal hematoma in 17 (16%) and 41 (38%) patients in groups M and P, respectively; this difference was significant. Furthermore, the amount of bleeding at 6 h postoperatively was lower in group M than in group P (235 ± 147 vs. 284 ± 175 mL, p = 0.0275). Chest reopening, intubation time, and length of intensive care unit and hospital stays did not differ between the groups. The evaluation of substernal hematoma based on computed tomography yielded a significantly lower for group M than for group P, revealing that the mesh plate was an independent predictor of substernal hematoma prevention. Conclusion Sternal fixation with a three-piece bioresorbable mesh plate could prevent postoperative sternal displacement, bleeding, and substernal hematoma more than sternal fixation with a pin.

Bard 5954810 Ventralight ST Mesh 8 x 10. 20.3cm x 25.4cm

New BARD 5950008 Ventralex ST Hernia Patch Self-Expanding Bioresorbable Coated Permanent Mesh Patch And Strap, 6.4cm/2.5 (X) Disposables - General For Sale - DOTmed Listing #3494516

Materials and techniques in chest wall reconstruction: a review - Sanna - Journal of Visualized Surgery

A comparative study of two types of sternal pins used for sternal closure: poly-l-lactide sternal pins versus uncalcined hydroxyapatite poly-l-lactide sternal pins

The Collection 2022 - EN by Toppoint - Issuu

MTMRecognition - Commonwealth of Virginia

Three-dimensional (3D)-reconstruction of a sternum dehiscence.

Development of Bioresorbable Self Expanding Implantable Neurovasc

Recent progress in biodegradable and bioresorbable materials: From passive implants to active electronics - ScienceDirect

PDF) Deep sternal wound infection after cardiac surgery

100-21-0, MFCD00002558, Terephthalic acid

Phenomenon of dancing wires in total sternal dehiscence (male, 62

Articles of poly(butylene succinate) and copolymers thereof Patent Grant Williams , et al. May 4, 2 [Tepha, Inc.]